arcoPlus® 547
Modular system of multiwall UV protected polycarbonate for windows and translucent roofing applications.
arcoPlus®547 is a modular system of coextruded 7 walls polycarbonate panels with a thickness of 40mm, aluminum profiles, accessories and opening windows, designed for simple and versatile use.
arcoPlus®547 can be used for roofing applications with a minimum slope of 7%.
Product Profile
Production Standards
- thickness – 40mm
- structure- 7 walls
- effective modular width – 333mm (347) – 500mm (547)
- panel length – no limit
- colors available – see page 11 of our catalog
Plastic Glazing Specifications
Technical Features
- Thermal insulation – 1.1 W/m2K
- U-Value (R=1/U) – 0.188
- Acoustic insulation – 22 dB
- Linear thermal expansion – 0.065 mm/m°C
- Temperature range – -40°C +120°C
- U.V. rays protection – Coextrusion
- Fire reaction ASTM E84 Class A
Color | Light transmission (LT) % | Solar Heat Gain Coefficient (SHGC) | Shading coefficient (SC) |
Clear | 67 | 68 | 0.78 |
Green | 60 | 57 | 0.66 |
Bronze | 45 | 50 | 0.57 |
Opal | 44 | 45 | 0.52 |
❖ Easy and low-cost installation
❖ Light transmission
❖ Resistance to U.V. rays and to hail
❖ Heat insulation
❖ High load resistance
Applications
❖ Vertical windows
❖ Roofing
Easy and Low Cost Installation.
The 40mm-thick, 7 walls design with tongue and groove connection gives the panels remarkable flexural strength. It also allows the panels to be installed without the use of metal reinforcement frames (continuous glazing), thus eliminating heat loss due to the thermal bridges caused by these structures (discontinuous glazing).
For installations exceeding 2.2m, a suitable section-breaker profile must be installed to which the arcoPlus® panels can then be fixed. This is done using the specific brackets to give the system the necessary resistance to negative wind load and permit sliding due to thermal expansion (see load resistance graph).
Examples of Panel Length
In addition to a complete range of aluminum profiles (also available as thermally insulated) for installing the panels, the system also includes opening windows (manually operated or motorized) to ventilate the building (see opening systems on page 70).
The air cells of the polycarbonate panels must be sealed using vented aluminum breather tape.
This allows correct ventilation and prevents soiling on the inside.
Insertion of Plate
Side Profile
Base Profile with TT
Metal Profiles
Accessories
Click on a link below to open or right click the link to download.
547 Cross Section (DWG)
547 (DWG)
547 (DXF)
547 (PDF)
4045 Channel (DWG)
4047 Channel (DWG)
4050 Clip (DWG)
4052 (DWG)
4052 (DXF)
4140 2 PC Base (DWG)
4312 Water Infiltration (DWG)